Generator Update configuration register
GLOBAL_UP_EN | Configures whether or not to enable global update for all active registers in MCPWM module.\0: Disable\1: Enable |
GLOBAL_FORCE_UP | Configures the generation of global forced update for all active registers in MCPWM module. A toggle (software invert its value) will trigger a global forced update. Valid only when MCPWM_GLOBAL_UP_EN and MCPWM_OP0/1/2_UP_EN are both set to 1. |
OP0_UP_EN | Configures whether or not to enable update of active registers in PWM operator0. Valid only when PWM_GLOBAL_UP_EN is set to 1.\0: Disable\1: Enable |
OP0_FORCE_UP | Configures the generation of forced update for active registers in PWM operator0. A toggle (software invert its value) will trigger a forced update. Valid only when MCPWM_GLOBAL_UP_EN and MCPWM_OP0_UP_EN are both set to 1. |
OP1_UP_EN | Configures whether or not to enable update of active registers in PWM operator1. Valid only when PWM_GLOBAL_UP_EN is set to 1.\0: Disable\1: Enable |
OP1_FORCE_UP | Configures the generation of forced update for active registers in PWM operator1. A toggle (software invert its value) will trigger a forced update. Valid only when MCPWM_GLOBAL_UP_EN and MCPWM_OP1_UP_EN are both set to 1. |
OP2_UP_EN | Configures whether or not to enable update of active registers in PWM operator2. Valid only when PWM_GLOBAL_UP_EN is set to 1.\0: Disable\1: Enable |
OP2_FORCE_UP | Configures the generation of forced update for active registers in PWM operator2. A toggle (software invert its value) will trigger a forced update. Valid only when MCPWM_GLOBAL_UP_EN and MCPWM_OP2_UP_EN are both set to 1. |